Repository logo
Communities & Collections
All of Repository
  • English
  • العربية
  • বাংলা
  • Català
  • Čeština
  • Deutsch
  • Ελληνικά
  • Español
  • Suomi
  • Français
  • Gàidhlig
  • हिंदी
  • Magyar
  • Italiano
  • Қазақ
  • Latviešu
  • Nederlands
  • Polski
  • Português
  • Português do Brasil
  • Srpski (lat)
  • Српски
  • Svenska
  • Türkçe
  • Yкраї́нська
  • Tiếng Việt
Log In
New user? Click here to register.Have you forgotten your password?
  1. Home
  2. Browse by Author

Browsing by Author "FIRAOL KASAHUN MENGESHA"

Filter results by typing the first few letters
Now showing 1 - 1 of 1
  • Results Per Page
  • Sort Options
  • No Thumbnail Available
    Item
    ENHANCING THE RELIABILITY OF DISTRIBUTION SYSTEM THROUGH RENEWABLE ENERGY RESOURCES
    (Hawassa University, 2024-04-12) FIRAOL KASAHUN MENGESHA
    The distribution system connects high-voltage transmission networks with end-users. Most of the time, power plants are situated distant from the consumer's location, resulting in large power losses in both the distribution and transmission systems, However, distribution system losses are typically greater than transmission line side losses. The main objective of this study is to reduce power losses and enhance system reliability using Distributed Generation (DG) in the case of the Guder Substation. The Guder Substation has three feeder lines that provide energy for different customers. From these feeders, the Guder town feeder has been chosen since it is frequently interrupted. The chosen feeder has been modeled in ETAP software, and simulation results have been obtained with both ETAP and MATLAB software. The results show that the feeder has a power loss of 611.9843 KW and 323.8237 kVar active and reactive, respectively. Additionally, the study investigates the existing reliability indices of SAIFI, SAIDI, and EENS, which have values of 303.7458 f/cust.yr, 306.4240 hr/cust.yr, and 2368.307 MWhr/yr, respectively. Particle Swarm Optimization algorithm has been suggested to decide the best size and position of DG. After renewable Distributed Generation penetrated the network, the real and reactive power loss reduced from 611.9843 KW and 323.8237 kVar to 302.75 KW and 132.34 kVar, respectively. Additionally, the SAIFI, SAIDI, and EENS system reliability indices were enhanced from 303.7458 f/cust.yr, 306.4240 hr/cust.yr, and 2368.307 MWhr/yr to 27.4968 f/cust.yr, 13.650 hr/cust.yr, and 111.758 MWh/yr, respectively. Finally, reliability indices and line losses before and after Distributed Generations penetrated the network are compared. In general, the simulation results indicate that the suggested method is efficient in maintaining system reliability and minimizing power losses
Useful Links
  • Web Site
  • E-Learning
  • Library
  • SIS
  • Portal
Library Contact

Library Service Directorate

Phone: +251 46 212 2594

Email: library@hu.edu.et

Repository Links
  • Home
  • Browse Collections
  • Submit Research
  • Help & Support
Copyright © 2026, Hawassa University.