COMPARISON OF TIES CONFIGURATION FOR COLUMN UNDER COMPRESSIVE LOAD
No Thumbnail Available
Date
2018-10-16
Authors
Journal Title
Journal ISSN
Volume Title
Publisher
Hawassa University
Abstract
A tied column in the reinforced concrete structure is the one in which longitudinal bars are tied
together with smaller diameter bars at intervals up the column. In Ethiopia most building in the
seismic area have tied column. Ties should confine core concrete properly. One way to enhance
confinement is using proper detailing, seismic hook. However, installation (bending) of confining
reinforcement with a 135-degree hook (seismic hook) is not easy. Therefore, in practice, many
construction workers in most part of our country with high seismic zones: Zone 3 and Zone 4 apply
a confining reinforcement with a 90-degree hook (fixed by wire mesh) .But most of the building
codes recommend using a 135-degree hook, especially in this seismic zones.
In the present study, a comparison of two type of ties configuration by taking 150x150x465(mm)
reinforced concrete specimens made. This study proposed two different type of ties configuration
Introduced category 3 (IC3) and Introduced category 4 (IC4) and compared with 900
ties
configuration under peak load and load-deformation behaviors. Three samples cast for each ties
configurations having 8mm ties and three plain concrete with the same size. Additionally, two
samples with similar geometry for 900
and 1350
compared having 6mm ties.
Concentric axial compression load applied with the universal testing machine and average axial
deformation were measured using linear voltage displacement transducer. The strain gauge was
placed in ties at mid-height of the column.
From observed experimental program ties with 900
configurations got the least performance for
both diameter ties, its peak axial strength was 23.24% lower than seismic hook configuration for
8 mm ties. Introduced configuration 3 (IC3) was in good proximity with standard 1350
hook; axial
peak load reduction of IC3 was 8.33% from 1350
hook. But IC4 result was similar to 900
ties
configuration. In addition to experimental study analytical and nonlinear finite element model for
8mm formulated and the result was in good agreement with a standard hoo